This ensures the virtual terminal processing mode is enabled on the rclone process
for Windows 10 consoles (by using Windows Console API functions GetConsoleMode/SetConsoleMode
and flag ENABLE_VIRTUAL_TERMINAL_PROCESSING), which adds native support for ANSI/VT100
escape sequences. This mode is default in many cases, e.g. when using the Windows
Terminal application, but in other cases it is not, and the default can also be
controlled with registry setting (see below), and therefore configuring it on the process
seem to be the only reliable way of ensuring it is enabled when supported.
[HKEY_CURRENT_USER\Console]
"VirtualTerminalLevel"=dword:00000001
Since rclone version 1.61.0 the tree command uses ANSI color sequences in output by
default, but this lead to issues in Windows terminals that were not handling these (#6668).
This commit ensures the tree command uses the terminal package for output. It relies on
go-colorable to properly handle ANSI color sequences: If stdout is connected to a terminal
the escape sequences are decoded and the text are written with color formatting using
Windows Console API. If stdout is not connected to a terminal, e.g. redirected to file,
the escape sequences are stripped off. The tree command has its own method for writing
directly to a file, specified with flag --output, and then the output is not passed
through the terminal package and must therefore be written without ansi codes.
Before this change the hash used for Onedrive Personal was SHA1. From
July 2023 Microsoft is phasing out SHA1 hashes in favour of
QuickXorHash in Onedrive Personal. Onedrive Business and Sharepoint
remain using QuickXorHash as before.
This choice can be changed using the --onedrive-hash-type flag (and
config option) so that SHA1 can be selected while it is still
available in the transition period.
See: https://forum.rclone.org/t/microsoft-is-switching-onedrive-personal-to-quickxorhash-from-sha1/36296/
Before this change if an --s3-profile was set which used AWS STS (eg
to assume a role) and --s3-endpoint was set then rclone would use the
value from --s3-endpoint to contact the STS server which did not work.
This fix implements an endpoint resolver which only overrides the "s3"
service if --s3-endpoint is set. It sends the "sts" service (and any
other service) to the default resolver.
Fixes#6443
See: https://forum.rclone.org/t/s3-profile-failing-when-explicit-s3-endpoint-is-present/36063/
There were some places (e.g. deleting files) where we were using
--transfers instead of --checkers to control the concurrency when
files weren't being transferred.
These have been updated to use --checkers.
Before this change, all types of checkers showed "checking" after the
file name despite the fact that not all of them were checking.
After this change, they can show
- checking
- deleting
- hashing
- importing
- listing
- merging
- moving
- renaming
See: https://forum.rclone.org/t/what-is-rclone-checking-during-a-purge/35931/
The block size for crypt is 64k + a few bytes. The default block size
for sftp is 32k. This means that the blocks for crypt get split over 3
sftp packets two of 32k and one of a few bytes.
However due to a bug in pkg/sftp it was sending 32k instead of just a
few bytes, leading to the 65% slowdown.
This was fixed in the upstream library.
This bug probably affected transfers from over the network sources
also.
Fixes#6763
See: https://github.com/pkg/sftp/pull/537
Before this change if --s3-no-head was in use rclone didn't check the
multipart upload ETag at all. However the ETag is returned in the
final POST request when completing the object.
This change uses that ETag from the final POST if --s3-no-head is in
use, otherwise it uses the ETag from a fresh HEAD request.
See: https://forum.rclone.org/t/in-some-cases-rclone-does-not-use-etag-to-verify-files/36095/
No need to report hours, minutes, and even seconds when the
ETA is several years, e.g. "292y24w3d23h47m16s". Now only
reports the 3 most significant units, sacrificing precision,
e.g. "292y24w3d", "24w3d23h", "3d23h47m", "23h47m16s".
Fixes#6381
Integer overflow would lead to ETA such as "-255y7w4h11m22s966ms",
as reported in #6381. Now the value will be clipped at the maximum
"292y24w3d23h47m16s", and it will be shown as infinity.
Explicitly set ARM version in GOARM build variable, to avoid relying
on some default value which differs when compiling natively and when
cross-compiling, and which is also incorrectly documented as being
6 when in reality it is 5.
Fix incorrect labelling of ARMv5 builds as ARMv6, and change
architecture of .rpm and .deb packages containing them to
match.
Add ARMv6 builds, to complement existing ARMv5 and ARMv7, and to
reduce disruption due to previous ARMv5 builds incorrectly being
identified as ARMv6, and to provide .rpm and .deb packages with the
same ARMv6 architectures as was previously also published
(then containing ARMv5 binaries).
See #6528
Background info:
https://github.com/golang/go/wiki/GoArmhttps://go.dev/doc/install/source#environment661e931dd1/src/cmd/dist/build.go (L140-L144)661e931dd1/src/cmd/dist/util.go (L392-L422)